Series BUP Heatless Adsorption Dryers from Boge

Heatless Adsorption Dryers

Flow Capacity: 3 - 60 cfm
Max. Operating Pressure: 250 psi

INLET AND OUTLET VALVES
The generously dimensioned inlet and outlet valves ensure a lower pressure differential across the dryer. Energy savings are therefore possible due to tighter operating pressure band.

REGENERATION
The twin tower system allows regeneration simultaneously with the adsorption eliminating the need for any external power supply. The wet tower is purged via a stream of dry air that is finally vented to atmosphere.

FILTRATION
The entire range is equipped with both pre and after filter as standard. Even before drying, all solids and aerosols up to 0.01 µm are removed from the compressed air supply – assuring best possible quality.

DEW POINT CONTROL
The entire series is available with dew point control that minimizes the regeneration air volume depending on temperature, pressure and output quantity thus reducing operating costs.

The easy way to dry compressed air:
The standard BOGE adsorption dryers achieve a pressure dew point of -40°F. They can be configured to reach -70°F. Such dewpoints eliminate the risk of downstream condensate especially in the case of an external air line. Adsorption dryers do not contain any CFCs and are therefore neither ozone depleting nor do they have any impact on the environment.

Model Capacity Regeneration Air (14.5 psi. +68°F) Air Outlet (minimal) (14.5 psi. +68°F) Pressure Loss New Condition Dimensions H/W/D Compressed Air Connection Weight
m³/h cfm m³/h cfm m³/h cfm psi in. lbs.
BUP 0003 5 3 0.85 0.5 4.1 2.4 0.94 12 x 5 x 14 ½" NPT 15
BUP 0005 10 5 1.70 1.0 8.1 4.8 1.37 12 x 5 x 23 ½" NPT 24
BUP 0010 15 10 2.55 1.5 12.2 7.2 1.67 12 x 5 x 34 ½" NPT 33
BUP 0015 25 15 4.25 2.5 20.3 11.9 3.63 12 x 5 x 55 ½" NPT 53
BUP 0020 35 20 5.95 3.5 28.4 16.7 1.09 21 x 7 x 26 1" NPT 64
BUP 0030 50 30 8.50 5.0 40.6 23.9 1.45 21 x 7 x 36 1" NPT 84
BUP 0040 65 40 11.10 6.5 52.8 31.1 1.81 21 x 7 x 46 1" NPT 106
BUP 0050 80 50 13.60 8.0 65.0 38.2 2.47 21 x 7 x 56 1" NPT 125
BUP 0060 100 60 17.00 10.0 61.3 36.0 3.63 21 x 7 x 66 1" NPT 147






Dimensions for series BUP Heatless Adsorption Dryers from Boge

Design: BUP 0003 - BUP 0060, Correction factor F

Temperature Operating pressure psi
58 73 87 102 116 131 145 160 174 189 203 218 232
77°F 0.69 0.82 0.96 1.10 1.24 1.38 1.50 1.50 1.50 1.50 1.50 1.50 1.50
86°F 0.69 0.82 0.96 1.10 1.24 1.38 1.50 1.50 1.50 1.50 1.50 1.50 1.50
95°F 0.63 0.75 0.88 1.00 1.13 1.26 1.38 1.50 1.50 1.50 1.50 1.50 1.50
104°F 0.48 0.58 0.68 0.77 0.87 0.96 1.06 1.16 1.25 1.35 1.45 1.50 1.50
113°F 0.38 0.45 0.53 0.60 0.68 0.75 0.83 0.90 0.98 1.05 1.13 1.20 1.28
122°F 0.30 0.36 0.42 0.48 0.54 0.60 0.66 0.72 0.78 0.84 0.90 0.96 1.02

Example Compressed air to be dried

Volume Flow 350 scfm
Min. operating pressure 150 psig
Max. inlet temperature 100 ˚F
Pressure dew point 1.38
Equation to Determine Which BUP Model