Microfilter and Activated Carbon Particulate Filters





Series BV Prefilters from Boge

Pre-filter BV



EFFICIENT BOGE
pre-filters are 99.99 percent efficient based on 3 µm, thus providing optimal conditions for further compressed air treatment.

LAYOUT
It is recommended that a pre-filter is positioned upstream of the compressed air dryer and the microfilter. They are essential when ambient air is extremely dusty or when high oil carry over is a risk.



Series BM Microfilters and BA Activated Carbon Filters from Boge

Microfilter BM and active carbon filter BA

EFFICIENT
BOGE microfilters are 99.99 percent efficient based on 0.01 µm. The residual oil content after a microfilter is 0.01 ppm, and reduced to 0.005 ppm when used in combination with active carbon filters.

LAYOUT
Microfilters with or without active carbon filters are best used as main filters in the compressed air line or as point of use filters.


Differential pressure and efficiency

Differential pressure in clean condition BM Series BA Series BV Series
Δp 1.3 psid Δp 1.45 psi Δp 0.7 psi
Efficiency 99.99999 % relative to 0.01 μm Residual oil content max. 0.01 ppm Residual oil content = 0.003 ppm 90% on ISO fine dust Residual Oil content 1 ppm

For ultra clean compressed air in extreme conditions:
Compressed air treatment is achieved in several stages. Pre-filters are used to separate coarse impurities from the compressed air. Smaller solids and oil can be removed by means of microfilters. Finally active carbon filters are used to clean oil vapors, aromatics, flavorings and odors from the compressed air. This assures oil free and clean compressed air even in extreme conditions!


Model Capacity
Connection
Element Dimensions (in) Weight Filter Element
scfm in. fnpt size quantity H W lbs. type
BDF Series Filters
BDF 0120 70 1⁄2" 120 1 13.5 4.5 2 BM,BV
BDF 0210 123 3⁄4" 210 1 14.5 6 5 BM,BV
BDF 0320 188 1" 320 1 17.5 6 5 BM,BV,BA
BDF 0450 264 11/4" 450 1 23 7.5 12 BM,BV
BDF 0600 353 11/2" 600 1 23 7.5 12 BM,BV
BDF 0750 441 2" 750 1 23 7.5 12 BM,BV
BDF 1100 647 2" 1100 1 30 7.5 16 BM,BV,BA
BDF 1700 1000 21/2" 2030 1 37 7 29 BM,BV,BA
BDF 2500 1500 3" 3030 1 47 7 31 BM,BV,BA

Filter capacity based on nominal operating conditions at 100 psig inlet pressure at 100°F as per ISO 12500
Maximum operating pressure 250 psig
Maximum operating inlet temperature 150°F




Series BDF Microfilters from Boge

Conversion factor f at other operating pressures

PSI Over-pressure 15 30 45 60 75 90 100 130 150 160 175 190 200 220
f = 0.25 0.36 0.5 0.6 0.75 0.9 1 1.2 1.4 1.5 1.6 1.75 1.9 2

Higher pressures and capacities are available upon request

Filter types

BV - Particulate / Coalescing Filter
Initial Dp Residual Oil Particle Retention Rate
0.7 (psid) 1 ppm 90% on ISO fine dust
BM - Coalescing Filter
Initial Dp Residual Oil Particle Retention Rate
1.3 (psid) 0.004 ppm 99.9999% on .01 micron
BA - Activated Carbon Filter
Initial Dp Residual Oil Particle Retention Rate
1.45 (PSID) <0.003 ppm N/A